High-Speed Digital Thermometer
• Highest accuracy in 10 seconds • Flexible tip • Hypoallergenic tip Technical specifications Type: Maximum thermometer Measuring range: 32.0 °C to 42.9 °C Temp. < 32.0 °C: display «L» for low (too low) Temp. > 42.9 °C: display «H» for high (too high) Measurement accuracy: ± 0.1 °C between 34 °C and 42 °C ± 0.2 °C; 32.0 - 33.9 °C and 42.1 - 42.9 °C Operating conditions: 10–40 °C; 15–95% maximum relative humidity Storage conditions: -25 - +60 °C; 15-95 % maximum relative humidity Battery: LR41 (1.5V) / SR41 (1.55V) Battery life: approximately 2700 measurements (with a new battery) IP Class: IP67 Reference to standards: EN 12470-3, clinical thermometers; ASTM E1112; IEC 60601-1; IEC 60601-1-2 (EMC); IEC 60601-1-11 Expected lifespan: 5 years or 10,000 measurements - clinically tested This device complies with the standards of the Medical Device Directive aids 93/42/EEC. Technical changes reserved.
What is this medicine used for? Measuring body temperature
Directions for use Turn on the thermometer To turn on the thermometer, press the ON/OFF button 1; a A short beep indicates that the thermometer is switched on. A display test in progress. All function options are displayed. The last measurement will automatically be shown on the display 2 for 2 seconds with the "M" symbol. At a room temperature of less than 32 °C, the symbol «L» in the display, then the symbol «°C» flashes in the display 2. The thermometer is now ready for use. Function test The thermometer's operation is automatically tested every time when it is turned on. If a defect is detected (measurement inaccurate), this is indicated by "ERR" in the display, and measuring is no longer possible. In this case, the thermometer must are replaced.
Using the thermometer Select the desired measurement method. During measurement, the current
temperature is displayed continuously and the «°C» symbol flashes. If a beep sounds 10 times and the "°C" no longer flashes, then the temperature measured and can be read. When the temperature is higher than 37.5 °C, 10 beeps will sound to alert the patient that he/she may have a fever have. Reference: Orally measured temperature. To compare measurement results you must wait at least 1 minute to measure interval. To extend battery life, you can use the thermometer switch off by briefly pressing the ON/OFF button 1. Otherwise, the thermometer switches off automatically after approximately 10 minutes.
Measurement methods / Normal body temperature Under the armpit (auxillary) / 34.7 - 37.3 °C Pat your armpits dry with a towel. Place the measuring sensor 4 under the arm in the middle of the armpit, so that the point touches the skin touch and place the arm next to the body. This ensures that the room temperature does not affect the measurement, because the armpit is more
needs time to reach a temperature. Wait 5 minutes, regardless of the beeping sound. In the mouth (oral) / 35.5 - 37.5 °C Do not eat or drink anything hot or cold 10 minutes before the measurement. The mouth must remain closed until 2 minutes before starting the measurement. Place the thermometer under the tongue, to the left or right of the frenulum. The tip of the thermometer should make good contact with the tissue 4. Close your mouth and breathe evenly through your nose to to prevent the measurement from being influenced by breathing via the mouth. If this is not possible due to blocked airways, a different measurement method must be used. Measuring time approx.: 10 seconds! In the anus (rectal) / 36.6 - 38.0 °C Carefully insert the thermometer's measuring sensor 4 2 to 3 cm in the anal opening. The use of a protective cap and the use of Vaseline is recommended. If you are unsure about this measurement method, consult a professional to be consulted for guidance/training. Measuring time approx.: 10 seconds!
Cleaning and disinfecting For disinfection in a home environment, use a cotton swab of 70% isopropyl alcohol or a cotton swab moistened with 70% isopropyl alcohol to remove dirt from the thermometer probe. sweep (note: consider application and safety instructions of the disinfectant manufacturer). Always start by wiping from the end of the thermometer probe (approximately in the middle of the thermometer) towards the thermometer tip. Then the entire thermometer probe (see number 5 in the drawing) immersed in 70% isopropyl alcohol for at least 70% 5 minutes (max. 24 hours). Allow the disinfectant to dry after immersion. Dry for 1 minute before next use. Soak or wipe it do not screen to prevent blurring. The thermometer is not intended for professional use.
When the symbol «» appears on the display, the battery is empty and needs to be replaced. To replace the battery
the battery compartment cover must be removed 3. Place a new battery with the + side on top. Make sure you have a battery of the same type at hand. Batteries can be used in almost all electronics stores are bought.
Ingredients Thermometer
Warnings Follow the instructions for proper use. This documentation provides you with important operating and safety instructions for this appliance. Read this documentation carefully before using the appliance and keep it for future reference. - This device is only to be used for measuring human body temperature via oral, rectal or axillary routes. Do not attempt to take temperatures in other places, such as in the ear, as this may lead to inaccurate measurements and injury. - Do not use this appliance if you suspect it is damaged or if you notice anything unusual.
- We recommend cleaning this appliance according to the cleaning instructions before first use for personal hygiene. - The measuring time until the sound signal must be adhered to as a minimum without exception! - Please note that multiple measurements may be required for different measurement locations even after the beep Do not attempt rectal measurements on individuals with rectal conditions. This may worsen the condition. - Only allow children to use the appliance under adult supervision. Small parts can be swallowed. Be aware of the risk of entanglement if the appliance is equipped with cables or hoses. Do not use the device near strong electromagnetic fields, such as those from mobile phones or radios. Maintain a distance of at least 3.3 meters from such devices when using this device. - Protect the instrument from shocks and falls! - Do not bend the thermometer probe more than 45°!
Avoid ambient temperatures above 60°C. NEVER boil the instrument! - Only use the disinfectants listed in the Cleaning and Disinfecting section to clean the device to avoid damage to the device. We recommend having this device tested for accuracy every two years or after mechanical impact (e.g., dropping). Contact your local Microlife dealer for this.
WARNING: The temperature measured with this device is not a diagnostic! Do not rely solely on the measured result.
Storage advice Batteries and electronic instruments should be disposed of according to local regulations and not with household waste.
Store at a temperature between -25°C and 60°C
Other information Warranty This appliance has a lifetime warranty from the date of purchase. During this warranty period, Microlife will replace the defective product free of charge. repair or replace. Opening or modifying the device will void the warranty. invalid.
The following items are excluded from the warranty: - Transportation costs and transportation risks. - Damage caused by improper use or non-compliance with the instructions for use. - Damage caused by leaking batteries. - Damage caused by dropping or misuse. - Packaging/storage material and instructions for use. - Regular checks and maintenance (calibration). - Accessories and consumables: Battery. If warranty is required, please contact the dealer where you purchased it. product you purchased, or with your local Microlife service.
You can via Contact your local Microlife dealer via our website: www.microlife.com/support The compensation is limited to the value of the product. The warranty will be granted if the complete product is returned with the Original invoice. Repair or replacement within the warranty period or does not extend the warranty period. The statutory claims and rights of consumers are not limited by this warranty. Medical device. Read the instructions for use before use.