{"product_id":"medisana-medinose-compact-1-stuks","title":"Medisana Medinose compact 1 Piece","description":"\u003cb\u003eMedisana Medinose compact\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e Technical data\u003cbr\u003e Name and model: medisana Anti-allergy device\u003cbr\u003e for the nose Medinose Compact\u003cbr\u003e (model AN-6016)\u003cbr\u003e Power supply: 2 × 3V, CR2032 alkaline\u003cbr\u003e Duration of use of the\u003cbr\u003e batteries:\u003cbr\u003e approx. 30 treatments\u003cbr\u003e (3 minutes each time)\u003cbr\u003e Technology: phototherapy through two\u003cbr\u003e different wavelengths\u003cbr\u003e (652 nm and 940 nm)\u003cbr\u003e Application site: nostrils\u003cbr\u003e Classification: internal power supply, type BF, IP22, none\u003cbr\u003e AP or APG, continuous operation\u003cbr\u003e Type of light emission: continuous\u003cbr\u003e Light power: 3mW – 6mW\u003cbr\u003e Operating time: approx. 3 minutes\u003cbr\u003e Operating environment: Temperature: 15°C – 40°C\u003cbr\u003e humidity: 30% RH – 85% RH\u003cbr\u003e ambient pressure: 80 kPa – 105 kPa\u003cbr\u003e Storage and\u003cbr\u003e transport conditions: temperature: −20°C – 60°C,\u003cbr\u003e humidity: 30% RH – 85% RH\u003cbr\u003e ambient pressure: 80 kPa – 105 kPa\u003cbr\u003e Lifespan: 3 years, under normal\u003cbr\u003e terms of use\u003cbr\u003e Dimensions (L × W × H): approx. 70 × 39 × 17 mm\u003cbr\u003e Weight: approx. 21 g\u003cbr\u003e - Effective relief of allergic rhinitis (e.g. runny nose and sneezing) \r \u003cbr\u003e- Drug-free: Infrared and red light therapy\u003cbr\u003e - 3 minutes of use time\u003cbr\u003e - Wireless and compact design\u003cbr\u003e - Convenient one-button operation\u003cbr\u003e - With protective cover and cap\u003cbr\u003e - Batteries included\u003cbr\u003e - Certified medical device\u003cbr\u003e\u003cbr\u003e \u003cb\u003eWhat is this medicine used for?\u003c\/b\u003e\u003cbr\u003e Effective relief of allergic rhinitis (e.g. runny nose and sneezing)\u003cbr\u003e\u003cbr\u003e \u003cb\u003eDirections for use\u003c\/b\u003e\u003cbr\u003e Installing batteries\u003cbr\u003e • Open the battery compartment on the bottom of the base unit 1.\u003cbr\u003e (See fig. 9.)\u003cbr\u003e • Insert two CR2302 batteries. Pay attention to the polarity.\u003cbr\u003e (See fig. 0.)\u003cbr\u003e • Close the battery compartment.\u003cbr\u003e\u003cbr\u003e Notes on the batteries\u003cbr\u003e • If you hear a buzzer five times in a row, the batteries are (almost) empty. Replace the old batteries with new ones.\u003cbr\u003e • Remove the batteries if you will not be using the device for one month (or longer). This prevents damage to the device from battery leakage.\u003cbr\u003e • Batteries (i.e. rechargeable batteries) are not suitable.\r \u003cbr\u003e• Do not use a new battery together with a used battery.\u003cbr\u003e Do not use batteries of different types.\u003cbr\u003e • Do not allow battery acid to come into contact with your eyes. If this does happen, immediately rinse your eyes with plenty of clean water and consult a doctor.\u003cbr\u003e • Before inserting batteries, check that the battery compartment is intact and undamaged.\u003cbr\u003e Insert the nasal tube 4 into the base device 1.\u003cbr\u003e • Place the nosepiece 6 as far into the nose as is comfortable.\u003cbr\u003e Pressing the angle adjustment 5 on both sides makes it easier to insert and remove the nasal tube from the nose.\u003cbr\u003e • Press the on\/off button 2 to turn on the device. You'll hear a buzzer. The nosepieces 6 will begin to emit red light in two wavelengths.\u003cbr\u003e • A therapy cycle lasts approximately three minutes. The device then switches off automatically. Press the on\/off button 2 to switch off the device during treatment.\r \u003cbr\u003e• The Medinose Compact can be used three to five times a day with a break of five to six hours between treatments\u003cbr\u003e\u003cbr\u003e After finishing use\/cleaning\u003cbr\u003e • Remove the batteries if you will not be using the device for one month (or longer). This prevents damage to the device from battery leakage.\u003cbr\u003e • The device is not waterproof. Therefore, do not use liquid cleaning agents that could penetrate the device.\u003cbr\u003e • Clean the base unit and the nasal tube only with a soft, slightly damp cloth. Do not allow water to enter the unit.\u003cbr\u003e Make sure everything is hygienically clean afterwards.\u003cbr\u003e\u003cbr\u003e • Do not make any modifications to the product that have not been approved by the manufacturer. Unauthorized modifications will void any warranty claims. Do not disassemble or repair the device or its components.\u003cbr\u003e • Do not carry out cleaning or maintenance work when the appliance is switched on!\r \u003cbr\u003e• Avoid high temperatures and direct sunlight. Do not immerse the device in water, as this will damage it.\u003cbr\u003e • If the appliance has been stored at very high or very low temperatures, allow it to acclimatise for approximately 2 hours (at the temperatures specified in Technical data, under \"Using environment\") before using it.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eIngredients\u003c\/b\u003e\u003cbr\u003e Medinose device, protective cap, batteries\u003cbr\u003e\u003cbr\u003e \u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003e Use the appliance only for its intended purpose, as described in the user manual. Using it for any other purpose will void the warranty.\u003cbr\u003e\u003cbr\u003e The device is not intended for commercial or medical purposes.\u003cbr\u003e • When children under the age of 16 use this product, they must be supervised by an adult.\u003cbr\u003e • The appliance is not suitable for children under 6 years of age.\u003cbr\u003e • Keep the appliance out of the reach of children.\r \u003cbr\u003e• Do not look directly into the light rays, even when using an optical aid (e.g. glasses).\u003cbr\u003e • Do not use the device near flammable gas (e.g., anesthetic gas, oxygen, or hydrogen) or a flammable liquid (e.g., alcohol). Do not use the device in an oxygen-enriched environment.\u003cbr\u003e • Do not use the device if you are near high-frequency equipment or are connected to it (e.g. for medical examinations).\u003cbr\u003e • The appliance must not be used near appliances that emit short waves or microwaves.\u003cbr\u003e • Use only accessories intended for the appliance and supplied by the manufacturer.\u003cbr\u003e • You may only clean the device yourself. Do not repair the device yourself if it is defective, as this will void any warranty claims and can no longer guarantee safe operation. Consult your specialist dealer and have repairs carried out only by medisana customer service.\r \u003cbr\u003e• Information on possible electromagnetic interference and other interactions between the Medinose Compact and other devices, as well as information on countermeasures, can be found in 'Information on Electromagnetic Compatibility'. To avoid possible interference from electromagnetic radiation emitted by other devices, we recommend keeping the Medinose Compact at least 30 cm away from such devices (e.g. Wi-Fi routers, microwave ovens). The Medinose Compact must not be used near active medical radio-frequency devices or near MRI devices.\u003cbr\u003e used, because its electromagnetic radiation is exceptionally high.\u003cbr\u003e • The device must not be used by multiple people to avoid the transmission of infections.\u003cbr\u003e • If you feel unwell or experience pain during use, stop use immediately and consult a doctor.\r \u003cbr\u003e• Do not drop, repair or modify the device yourself.\u003cbr\u003e • Do not immerse the appliance in water or other liquids.\u003cbr\u003e • If the appliance moves unexpectedly during use,\u003cbr\u003e If you behave in this way, please contact customer service.\u003cbr\u003e • Do not wrap the cable around your body as this may cause strangulation.\u003cbr\u003e • Swallowing batteries or battery acid can be extremely dangerous. Keep the device and batteries out of the reach of children and people with disabilities.\u003cbr\u003e • Any type of use not described in these instructions for use may result in potentially hazardous radiation emissions and must therefore be avoided.\u003cbr\u003e • The appliance should not be used if you are allergic to plastic.\u003cbr\u003e • The device is intended to be applied by the patient himself\u003cbr\u003e\u003cbr\u003e \u003cb\u003eStorage advice\u003c\/b\u003e\u003cbr\u003e Store at a temperature between -20 and +60°C\u003cbr\u003e\r \u003cbr\u003eThis device must not be disposed of with household waste. Every consumer is obligated to return all electrical or electronic devices, regardless of whether they contain harmful substances, to a recycling center or a store where a similar product is purchased, so that they can be disposed of and recycled in an environmentally friendly manner.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOther information\u003c\/b\u003e\u003cbr\u003e Warranty and repair conditions\u003cbr\u003e Our warranty described below does not affect your statutory rights. For warranty claims, please contact your retailer or the service department directly. Please specify the defect and include a copy of your purchase receipt if the appliance needs to be returned. The following warranty conditions apply.\u003cbr\u003e strength:\u003cbr\u003e Medisana products are covered by a 3-year warranty from the date of sale. In the event of a warranty claim, the date of sale must be proven with a purchase receipt or invoice.\r \u003cbr\u003e2. Defects resulting from material or manufacturing errors will be remedied free of charge within the warranty period.\u003cbr\u003e 3. Providing a warranty does not extend the warranty period for the device or replaced parts.\u003cbr\u003e 4. The following are excluded from the warranty:\u003cbr\u003e a. all damage caused by incorrect use, e.g. failure to comply with the instructions for use;\u003cbr\u003e b. damage resulting from a repair or intervention by the buyer or an unauthorized third party;\u003cbr\u003e c. transport damage that occurred on the way from the manufacturer to the consumer or during shipment to the service department;\u003cbr\u003e d. parts showing normal wear and tear.\u003cbr\u003e 5. Liability for direct or indirect consequential damage caused by the device is also excluded if the damage to the device is recognized as covered by the warranty.\u003cbr\u003e Medical device. Read the instructions for use before use.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eManufacturer \/ Distributor\u003c\/b\u003e\u003cbr\u003e Medisana GmbH,\n Carl Schurz Strasse 2,\n 41460 Neuss,\n Germany","brand":"Medisana","offers":[{"title":"1.00 Stuks","offer_id":61931940938058,"sku":"288722","price":19.95,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0924\/5497\/7866\/files\/4015588450556_A1N1.png?v=1779961072","url":"https:\/\/athomepharma.com\/en\/products\/medisana-medinose-compact-1-stuks","provider":"AtHomePharma","version":"1.0","type":"link"}