{"product_id":"medisana-in-515-ultrasone-inhalator-1-stuks","title":"Medisana IN 515 Ultrasonic Inhaler 1 Piece","description":"\u003cb\u003eMedisana IN 515 Ultrasonic inhaler\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e Portable ultrasonic nebulizer IN 515\u003cbr\u003e Technical data\r \u003cbr\u003eName and model: medisana portable ultrasonic nebulizer IN 515 (model: NBM-1)\u003cbr\u003e Power: 3 V, 2 x 1, 5 V batteries AA LR6 or 5 V \/ 1 A (via USB-C)\u003cbr\u003e Energy consumption: \u0026lt; 2VA\u003cbr\u003e Power consumption in standby mode: \u0026lt; 0.1mA\u003cbr\u003e Ultrasonic frequency: 110 kHz ±10 kHz\u003cbr\u003e Nebulization capacity: \u0026gt;0.2 ml\/minute\u003cbr\u003e Particle size (MMAD): \u0026lt;5μm\u003cbr\u003e Percentage of particles that penetrate deep into the lungs as a fine mist: ≥60%\u003cbr\u003e Types of liquid nebulizers: solution and suspension\u003cbr\u003e Position in which the nebulizer works optimally: vertical\u003cbr\u003e Maximum amount of inhalant: 10 ml\u003cbr\u003e Automatically switches off after 20 minutes\u003cbr\u003e Operating conditions: +10 °C - +40 °C, relative humidity 10-95%, air pressure 86-106 kPa\u003cbr\u003e Storage conditions: -20 °C - +70 °C, relative humidity 10-95%, atmospheric pressure 50-106 kPa\u003cbr\u003e Weight approx.: 108 g (without batteries)\u003cbr\u003e Product life: 3 years\u003cbr\u003e Item No.: 54590\u003cbr\u003e EAN number: 40 15588 54590 0\u003cbr\u003e Spare parts: art. 54591 mask for children for IN 515, EAN 40 15588 54591 7\r \u003cbr\u003eart. 54592 mask for adults for IN 515, EAN 40 15588 54592 4\u003cbr\u003e art. 54593 mouthpiece for IN 515, EAN 40 15588 54593 1\u003cbr\u003e\u003cbr\u003e \u003cb\u003eWhat is this medicine used for?\u003c\/b\u003e\u003cbr\u003e Breathe allergy-free with medisana's compact, quiet \u0026amp; portable inhaler against pollen, house dust \u0026amp; more\u003cbr\u003e\u003cbr\u003e \u003cb\u003eDirections for use\u003c\/b\u003e\u003cbr\u003e Usage: Restore power supply\u003cbr\u003e To use the medisana ultrasonic nebulizer IN 515 it can be powered by 2 x 1.5 AA batteries\u003cbr\u003e V or using the USB-C cable.\u003cbr\u003e a) Battery power supply:\u003cbr\u003e Open the battery compartment cover 7 on the bottom of the device in the direction of the arrow (see figure). Insert the\u003cbr\u003e 2 batteries included (type AA\/LR6 1.5 V). Make sure the batteries are inserted in the correct direction. Connect\u003cbr\u003e the battery compartment cover 7 again. Replace the batteries with new ones as soon as possible if the device is switched on.\u003cbr\u003e indicator light 3 orange flashes.\u003cbr\u003e\u003cbr\u003e b) Power supply using the USB-C cable:\r \u003cbr\u003eOpen the cover of the USB-C connector 1 and connect the USB-C cable to a suitable\u003cbr\u003e power source. This device cannot be used to charge rechargeable batteries.\u003cbr\u003e\u003cbr\u003e Preparation for use\u003cbr\u003e 1. Make sure the appliance is switched off.\u003cbr\u003e 2. Open the reservoir valve 5 and fill it with the inhaler (maximum capacity 10 ml = 10 ccm). Carefully read the instructions for use and dosage on the package insert of the medication you are using.\u003cbr\u003e 3. Close the reservoir cover 5 again. Check that the reservoir 5 is positioned correctly and hold the appliance upright.\u003cbr\u003e possible to prevent it from leaking.\u003cbr\u003e\u003cbr\u003e Inhale through the mouthpiece\u003cbr\u003e 1. Sit up as straight as you can.\u003cbr\u003e 2. Place the mouthpiece 4 on the device and close your lips completely around it.\u003cbr\u003e 3. Turn on the appliance by pressing the on\/off button 2. The indicator light 3 lights up green.\u003cbr\u003e 4. Now breathe in slowly and deeply through your mouth and out through your nose. You can improve the effectiveness of the therapy by\r \u003cbr\u003einhale to hold the air briefly. However, this is not necessary for a general result of the therapy. It is important\u003cbr\u003e that you remain calm and relaxed while breathing in and out evenly. Do not inhale too quickly. If you wish, you can take a short breath.\u003cbr\u003e pause and remove the mouthpiece 4 from your mouth. Put it back in your mouth (lips completely enclose it) and breathe in\u003cbr\u003e slowly in and out again.\u003cbr\u003e\u003cbr\u003e INSTRUCTIONS\u003cbr\u003e • Keep the appliance upright as much as possible. However, if it is tilted slightly, this will not have any\u003cbr\u003e influence on use. For optimal operation, make sure you hold the device as straight as possible while inhaling.\u003cbr\u003e keeps possible.\u003cbr\u003e • Move the device slightly when the amount of aerosol is almost used up, so that the remaining amount is better distributed.\u003cbr\u003e is distributed over the membrane.\u003cbr\u003e\u003cbr\u003e 5. A treatment should not last longer than 20 minutes.\u003cbr\u003e 6. When the reservoir 5 is empty, the indicator light 3 lights up red and the appliance switches off shortly afterwards. You can\r \u003cbr\u003eAfter inhaling, you can also switch it off manually by pressing the on\/off button 2, even if all the inhalant has been used.\u003cbr\u003e has not yet been used up.\u003cbr\u003e 7. Pour any remaining inhalant from the reservoir. Do not reuse it. Always clean the device immediately after use.\u003cbr\u003e clean. (See also \"Cleaning and maintenance\" and \"Disinfection\".) If the nozzle 4 is in use for a long time,\u003cbr\u003e During use, 2-3 drops of inhalant may appear in the mouthpiece tube. However, this does not affect\u003cbr\u003e on the use and operation of the device. Remove drops with a soft cloth after use.\u003cbr\u003e\u003cbr\u003e Inhaling with the mask\u003cbr\u003e An adult mask and a child mask are also included, which allow the aerosol to be expelled through the nose.\u003cbr\u003e are inhaled. Older people in particular find this application more pleasant.\u003cbr\u003e To inhale with the mask, the adult or child mask should be placed 4 inches on the outlet of the reservoir.\r \u003cbr\u003eare placed. Then follow the directions as described in \"Inhaling with the mouthpiece\". The difference is that the mouth\u003cbr\u003e does not close around the mouthpiece, but that the mask is held over the mouth and nose.\u003cbr\u003e\u003cbr\u003e Cleaning and maintenance\u003cbr\u003e • Remove the mask or mouthpiece from the device and pour out any remaining inhalant.\u003cbr\u003e • Never hold the entire device or the nebulizer unit under running water for cleaning and ensure that no water gets into it.\u003cbr\u003e the device arrives.\u003cbr\u003e • Start the cleaning mode of the device as follows: make sure the device is switched off and add 3-6 ml of clean water\u003cbr\u003e in the reservoir 5. Activate the cleaning mode by pressing the on\/off button 2 for 3 seconds. The\u003cbr\u003e Indicator light 3 flashes green slowly. Cleaning mode lasts for 3 minutes, and the device then exits this mode.\u003cbr\u003e by switching off automatically.\u003cbr\u003e • Now disconnect the power supply (remove batteries and\/or disconnect the USB-C cable).\r \u003cbr\u003e• Press the release button 6 on the back of the appliance and remove the reservoir 5.\u003cbr\u003e • Rinse the inside of the reservoir 5 with clean water for at least 3 minutes. Do not rinse the\u003cbr\u003e bottom of the cup, see image.\u003cbr\u003e • You can clean the housing of the device with a cloth slightly dampened in water.\u003cbr\u003e a mild cleaning agent.\u003cbr\u003e • Clean the mask or mouthpiece under running water.\u003cbr\u003e • Then allow all parts to air dry thoroughly on a dry, soft surface (e.g. a\u003cbr\u003e towel).\u003cbr\u003e • If the appliance has not been used for a long period of time and before using it for the first time,\u003cbr\u003e can also be cleaned in this way.\u003cbr\u003e\u003cbr\u003e Disinfect\u003cbr\u003e In case of infectious diseases, in addition to cleaning the device, you should also disinfect it by performing the following\u003cbr\u003e steps. We recommend that you perform the following actions regularly in the morning or evening.\u003cbr\u003e to be carried out at a fixed time in the evening:\u003cbr\u003e • Rinse the mask(s) and mouthpiece with distilled water.\r \u003cbr\u003e• Bring distilled water to the boil in a saucepan.\u003cbr\u003e • Place the mouthpiece in the boiling water for 5 minutes.\u003cbr\u003e • Then remove the parts from the water and leave them in the air (e.g. lying on a\u003cbr\u003e towel) dry and cool.\u003cbr\u003e • Instead of boiling distilled water, you can also soak the parts in a solution of\u003cbr\u003e 75% cleaning alcohol - they only need to sit in there for 1 minute.\u003cbr\u003e Then rinse the parts with distilled water and let them air dry.\u003cbr\u003e • Ensure that no residue of the disinfectant remains on the parts, as this would\u003cbr\u003e could otherwise pose a hazard the next time the appliance is used.\u003cbr\u003e used.\u003cbr\u003e\u003cbr\u003e Troubleshooting\u003cbr\u003e Problem: little\/no atomization\u003cbr\u003e Solution: Replace the batteries or check whether the power supply is working properly. Check whether the reservoir 5 is correctly positioned on the\u003cbr\u003e Check that the device is assembled and that there is sufficient aerosol in the reservoir. Clean the device.\r \u003cbr\u003eProblem: Indicator light 3 flashes green and then turns off\u003cbr\u003e Solution: The device has been in use for a long time. Turn off the device and wait a few minutes before turning it on again.\u003cbr\u003e used.\u003cbr\u003e Problem: Indicator light 3 flashes red and then turns off\u003cbr\u003e Solution: reservoir 5 empty or insufficient voltage.\u003cbr\u003e Problem: Indicator light 3 flashes orange and then turns off\u003cbr\u003e Solution: Replace the batteries or connect the USB-C cable correctly and ensure there is sufficient aerosol in reservoir 5.\u003cbr\u003e If the above instructions do not solve the problem, please contact customer service.\u003cbr\u003e Electromagnetic compatibility\u003cbr\u003e The device complies with the requirements of the EN 60601-1-2 standard for electromagnetic compatibility. Details\u003cbr\u003e You can find more information about these measurements in the product information sheet.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eIngredients\u003c\/b\u003e\u003cbr\u003e Inhaler\u003cbr\u003e\u003cbr\u003e \u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003e Safety instructions\r \u003cbr\u003e• When using an electronic device, basic safety precautions should always be followed, including the following instructions.\u003cbr\u003e • Use the appliance only for its intended purpose, as described in the user manual. Using it for any other purpose will void the warranty.\u003cbr\u003e • Any use other than that described above is considered improper and dangerous. If the appliance is not used as intended, responsibility for its safe operation transfers to the user.\u003cbr\u003e • Use only original (spare) parts from the manufacturer.\u003cbr\u003e • Use only liquid medications suitable for inhalation therapy. Consult your doctor or pharmacist about the duration, dosage, frequency of use, and choice of medications before starting therapy with the device.\r \u003cbr\u003e• When this device is used by children or people with disabilities, close supervision is necessary. The dosage and frequency of use should also be determined by the prescribing physician.\u003cbr\u003e • Do not use the appliance under a blanket or pillow. Excessive heat can cause fire, electric shock, or personal injury.\u003cbr\u003e • Follow the doctor's advice regarding the duration of treatment and take the medications recommended by the doctor.\u003cbr\u003e • Do not insert your finger or any object (e.g. cotton swab, etc.) into the opening of the device – risk of damage!\u003cbr\u003e • Do not repair the appliance yourself if it is defective. Have repairs carried out only by an authorized service center.\u003cbr\u003e • Do not open or modify the appliance.\u003cbr\u003e • This device is not suitable for use in an anaesthesia or ventilation device.\u003cbr\u003e\u003cbr\u003e Before use\r \u003cbr\u003e• The device is designed for use in an environment that meets the conditions as described in the technical\u003cbr\u003e data. Make sure you adhere to it.\u003cbr\u003e • Do not use the appliance if it is damaged or has fallen into water, but contact customer service.\u003cbr\u003e or send it in for repair.\u003cbr\u003e • Check that all parts are clean and disinfected. To prevent the risk of infection, follow the instructions and clean\u003cbr\u003e the appliance and its parts as described in the chapter \"Cleaning and Care\" or \"Disinfection\".\u003cbr\u003e • The reservoir 5 can be filled with a maximum of 10 ml. Never fill the reservoir beyond the marked maximum.\u003cbr\u003e • To prevent bacterial infection, never use the mouthpiece, adult mask and child mask with\u003cbr\u003e Multiple people. Each user must use their own mask or mouthpiece.\u003cbr\u003e During use\u003cbr\u003e • Never switch on the appliance if there is no aerosol in the reservoir 5.\r \u003cbr\u003e• Keep the appliance balanced and steady during use to avoid spills.\u003cbr\u003e • Do not open the reservoir lid during use.\u003cbr\u003e • Stop use immediately and consult your doctor if you experience any complaints during use.\u003cbr\u003e • This appliance has a timer that automatically switches off after 20 minutes. Every time the appliance is switched on\u003cbr\u003e restart this timer.\u003cbr\u003e • If the timer runs out or the appliance switches off due to another problem (e.g. insufficient power voltage,\u003cbr\u003e (If the aerosol is on) the indicator light 3 will light up red.\u003cbr\u003e After use\u003cbr\u003e • Clean or disinfect the device and its parts as described in the chapter \"Cleaning and maintenance\" or.\u003cbr\u003e \"Disinfecting\" in these instructions. Failure to follow these instructions may result in infections such as\u003cbr\u003e result of the growth of microorganisms.\u003cbr\u003e • Do not store the device or its parts where they will be exposed to direct sunlight, heat or moisture.\r \u003cbr\u003e• The appliance and its parts must not be cleaned in the dishwasher or dried in the microwave.\u003cbr\u003e • Always keep the appliance out of reach of children.\u003cbr\u003e\u003cbr\u003e BATTERY SAFETY INSTRUCTIONS\u003cbr\u003e • Do not take batteries apart!\u003cbr\u003e • Remove low batteries from the battery compartment immediately as they may leak and damage the device.\u003cbr\u003e damage!\u003cbr\u003e • Increased risk of leakage, avoid contact with skin, eyes and mucous membranes! In case of contact with battery acid, rinse the\u003cbr\u003e Immediately flush the affected area with plenty of clean water and consult a doctor immediately!\u003cbr\u003e • Consult a doctor immediately if a battery has been swallowed!\u003cbr\u003e • Always replace all batteries at the same time!\u003cbr\u003e • Only insert batteries of the same type, do not use different types or used and new batteries together!\u003cbr\u003e • Insert the batteries correctly, paying attention to the polarity!\u003cbr\u003e • Remove the batteries if you do not intend to use the device for at least 3 months.\r \u003cbr\u003e• Keep batteries away from children!\u003cbr\u003e • Do not recharge the batteries! There is a risk of explosion!\u003cbr\u003e • Do not short circuit! There is a risk of explosion!\u003cbr\u003e • Do not throw into an open fire! There is a risk of explosion!\u003cbr\u003e • Do not throw used batteries and accumulators into the household waste, but collect them separately or hand them in at a shop where batteries are recycled.\u003cbr\u003e are sold!\u003cbr\u003e\u003cbr\u003e \u003cb\u003eStorage advice\u003c\/b\u003e\u003cbr\u003e Store the appliance and all parts in a dry and clean place.\u003cbr\u003e • Make sure that there are no liquids left in reservoir 5 during transport and storage.\u003cbr\u003e • Remove the batteries if the device is not going to be used for a long period of time.\u003cbr\u003e • Do not store in places exposed to direct sunlight, extreme temperatures and high\u003cbr\u003e humidity.\u003cbr\u003e • Always keep the appliance away from fire, electromagnetic radiation and children.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOther information\u003c\/b\u003e\u003cbr\u003e Medical device. Read the instructions for use before use.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eManufacturer \/ Distributor\u003c\/b\u003e \u003cbr\u003emedisana GmbH,\n Carl-Schurz-Str. 2, ,\n 41460 NEUSS, ,\n Germany","brand":"Medisana","offers":[{"title":"1.00 Stuks","offer_id":61987595026762,"sku":"288721","price":29.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0924\/5497\/7866\/files\/4015588545900_A1N1_172101c7-b44f-454f-b94c-9fb63a55e7ab.png?v=1780902334","url":"https:\/\/athomepharma.com\/en\/products\/medisana-in-515-ultrasone-inhalator-1-stuks","provider":"AtHomePharma","version":"1.0","type":"link"}